Thermo Scientific™ Q Exactive™ GC Orbitrap™ GC-MS/MS

This instrument is a high-resolution/accurate-mass (HRAM) mass spectrometer capable of both electron impact and chemical ionization methods. This instrument is used for targeted analyses and for developing non-targeted methods. The tandem mass spec (MS/MS) capabilities, paired with accurate mass analysis, allow for increased confidence in unknown identifications. This instrument is also used for developing novel thermal desorption approaches for sample collection and analysis. This instrument was purchased with a Major Research Instrumentation grant from the National Science Foundation (CBET-1828257).  If interested in using this instrument for research, please contact Dr. Nick Herkert (Nicholas.Herkert@duke.edu) to inquire about access.

 

Thermo Scientific™ Exactive™ GC Orbitrap™ GC-MS

This instrument is a high-resolution/accurate-mass (HRAM) mass spectrometer capable of both electron impact and chemical ionization methods and provides the utmost confidence in compound discovery, identification, and quantitation. This instrument is used for targeted analysis of our large suite of semi-volatile organic compounds (SVOCs) in a range of sampling matrices, as well as for developing non-targeted analytical methods for identification of unknown compounds using accurate mass analysis and fragmentation patterns.

 

LCMS/MS

Agilent Liquid Chromatograph (Model 1260) Tandem Mass Spectrometer (Model 6460). This instrument is used to analyze sample extracts for more polar analytes, including urinary metabolites of organophosphate flame retardants. We also use this instrument to monitor and quantify phenolic contaminants, hydroxylated polybrominated diphenyl ethers (e.g. OH-BDEs), perfluorinated carboxylic acids (e.g. PFOA), perfluorinated sulfonic acids (e.g. PFOS), and thyroid hormones (e.g. T4, T3 and rT3) in a variety of sample matrices.

 

 

GCMS-EI

Agilent Gas Chromatograph (Model 7890A) Mass Spectrometer (Model 5975C) dedicated to electron impact ionization methods (GC/EI-MS). This instrument is one of our work horses in our laboratory, dedicated to the analysis of sample extracts for a large suite of semi-volatile organic compounds, including organophosphate flame retardants, organochlorine pesticides, polychlorinated biphenyls (PCBs), polycyclic aromatic hydrocarbons (PAHs), and phthalates.

 

 

 

GCMS-CI

Agilent Gas Chromatograph (Model 6890N) Mass Spectrometer (Model 5975) dedicated to chemical ionization methods (GC/ECNI-MS). This instrument is another one of our work horses, and is dedicated to the analysis of sample extracts for brominated flame retardants (e.g. PBDEs) and fluorotelomer alcohols (i.e. FTOHs).

 

 

 